Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Bioengineering (Basel) ; 11(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391634

RESUMO

PURPOSE: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. METHODS: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10-87), referred to as the "N group", and 314 KC eyes, aged 31.6 ± 10.8 (range 10-72), referred to as the "KC group", where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. RESULTS: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = -0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). CONCLUSIONS: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric.

2.
Eye Vis (Lond) ; 10(1): 45, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37919821

RESUMO

Different diagnostic approaches for ectatic corneal diseases (ECD) include screening, diagnosis confirmation, classification of the ECD type, severity staging, prognostic evaluation, and clinical follow-up. The comprehensive assessment must start with a directed clinical history. However, multimodal imaging tools, including Placido-disk topography, Scheimpflug three-dimensional (3D) tomography, corneal biomechanical evaluations, and layered (or segmental) tomography with epithelial thickness by optical coherence tomography (OCT), or digital very high-frequency ultrasound (dVHF-US) serve as fundamental complementary exams for measuring different characteristics of the cornea. Also, ocular wavefront analysis, axial length measurements, corneal specular or confocal microscopy, and genetic or molecular biology tests are relevant for clinical decisions. Artificial intelligence enhances interpretation and enables combining such a plethora of data, boosting accuracy and facilitating clinical decisions. The applications of diagnostic information for individualized treatments became relevant concerning the therapeutic refractive procedures that emerged as alternatives to keratoplasty. The first paradigm shift concerns the surgical management of patients with ECD with different techniques, such as crosslinking and intrastromal corneal ring segments. A second paradigm shift involved the quest for identifying patients at higher risk of progressive iatrogenic ectasia after elective refractive corrections on the cornea. Beyond augmenting the sensitivity to detect very mild (subclinical or fruste) forms of ECD, ectasia risk assessment evolved to characterize the inherent susceptibility for ectasia development and progression. Furthermore, ectasia risk is also related to environmental factors, including eye rubbing and the relational impact of the surgical procedure on the cornea.

3.
Vision (Basel) ; 7(2)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37218954

RESUMO

Biomechanics is a branch of biophysics that deals with mechanics applied to biology. Corneal biomechanics have an important role in managing patients with glaucoma. While evidence suggests that patients with thin and stiffer corneas have a higher risk of developing glaucoma, it also influences the accurate measurement of intraocular pressure. We reviewed the pertinent literature to help increase our understanding of the biomechanics of the cornea and other ocular structures and how they can help optimize clinical and surgical treatments, taking into consideration individual variabilities, improve the diagnosis of suspected patients, and help monitor the response to treatment.

4.
Curr Eye Res ; 48(2): 130-136, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35184637

RESUMO

Purpose: To prospectively review the importance of biomechanical assessment in the screening, diagnosis, prognosis, individualized planning, and clinical follow-up for ectatic corneal diseases.Methods: We demonstrate two commercially available devices to assess the corneal biomechanics in vivo, the Ocular Response Analyzer (ORA, Reichester, NY, USA) and the Corvis ST (Oculus, Wetzlar, Germany). Novel devices have been demonstrated to provide in vivo biomechanical measurements, including Brillouin optical microscopy and OCT elastography. Conclusion: The integration of biomechanical data and other data from multimodal refractive imaging using artificial intelligence demonstrated the ability to enhance accuracy in diagnosing ectatic corneal diseases.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Fenômenos Biomecânicos , Inteligência Artificial , Elasticidade , Córnea , Dilatação Patológica
5.
J Cataract Refract Surg ; 49(2): 190-194, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36201664

RESUMO

PURPOSE: To test the ability of the corneal epithelial pattern standard deviation (PSD) to distinguish between normal and cases with corneal ectatic condition. SETTING: Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil. DESIGN: Cross-sectional retrospective study. METHODS: Patients were stratified into 4 groups based on clinical data and corneal tomography. Groups 1 and 2 comprised 1 eye randomly selected from 105 patients with normal corneas (N) and 86 patients with bilateral keratoconus (KC). Groups 3 and 4, respectively, comprised 11 ectatic eyes with no surgical treatment for KC (very asymmetric ectasia [VAE]-E) from patients whose fellow eyes (61) presented with normal topographic patterns (VAE-NT). Corneas were scanned using an OCT system (RT Vue) and Scheimpflug corneal tomography (Pentacam) and also had biomechanical assessment through the Corvis ST. Corneal epithelial thickness maps were analyzed, and the PSD value was calculated. The area under the receiver operating characteristic curve analysis was used to evaluate the diagnostic accuracy of the indices. RESULTS: A total of 105 normal eyes, 86 keratoconic eyes, and 11 ectatic eyes whose fellow eyes (61) presented normal topographic patterns were evaluated. Epithelial PSD was significantly different across the 4 groups ( P < .0001). The pairwise comparison revealed that the normal group presented significantly lower values than both ectasia groups (KC and VAE-E, P < .0001) and the VAE-NT group ( P = .0008). There was no statistical significant difference between KC and VAE-E ( P = .4284), while they were significantly higher than the VAE-NT group ( P < .0001 and P = .0004). CONCLUSIONS: Epithelial PSD can be used to detect abnormal epithelial thickness patterns. Corneal epithelial thickness changes could be detected accurately in patients with KC, even in the form fruste of the disease.


Assuntos
Ceratocone , Humanos , Estudos Retrospectivos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Tomografia de Coerência Óptica , Paquimetria Corneana , Dilatação Patológica/diagnóstico , Estudos Transversais , Brasil , Córnea , Curva ROC
6.
Am J Ophthalmol ; 251: 126-142, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36549584

RESUMO

PURPOSE: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. DESIGN: Multicenter cross-sectional case-control retrospective study. METHODS: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. RESULTS: The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). CONCLUSIONS: AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Assuntos
Ceratocone , Humanos , Estudos Retrospectivos , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Inteligência Artificial , Dilatação Patológica/diagnóstico , Paquimetria Corneana/métodos , Estudos Transversais , Córnea/diagnóstico por imagem , Curva ROC , Tomografia/métodos
7.
Heliyon ; 8(11): e11699, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36468117

RESUMO

Purpose: To investigate the relationship between Ortho-K contact lens design parameters and refractive power change of the eye through a parametric mathematical representation. Methods: The current study utilises fully anonymized records of 249 eyes, 132 right eyes, and 117 left eyes from subjects aged 14.1 ± 4.0 years on average (range 9-38 years) which were selected for secondary analysis processing. The data were split into 3 groups (G1 up to 35 days wear, from 10 to 35 days, G2 up to 99 days wear, more than 35-99 days & G3 more than 100 days wear) according to the length of time, in days, that the lenses were worn. Corneal shape was measured before and after contact lens wear using the Medmont E300 topographer, from which height and distance files were read by a custom-built MATLAB code to construct the corneal anterior surface independently. Changes in refractive power pre and post-Ortho-K wear were determined using constructed tangential refractive power maps from which both centrally flattened and annular steepened zones were automatically bounded, hence used to determine the refractive power change. Results: On average, flat Sim-K and steep Sim-K were reduced after Ortho-K lens wear by 1.6 ± 1.3 D and 1.3 ± 1.4 D respectively. The radius of the base curve was correlated with the mean central flattened zone power change strongly in G1 (R = 0.7, p < 0.001) and moderately in G2 (R = 0.4) and G3 (R = 0.4, p < 0.001). Hence, a strong correlation with the base curve was recorded in group G1 and moderate in G2 and G3. The reverse curve was very strongly correlated to the mean central flattened zone power change in G1 (R = 0.8, p < 0.001) and strongly correlated with G2 (R = 0.6, p < 0.001) and G3 (R = 0.7, p < 0.001). The reverse curve was also strongly correlated with the mean annular steepened zone power change among all groups G1, G2, and G3 (R = 0.7, R = 0.6 and R = 0.6) respectively (p < 0.001). Conclusions: Although the central corneal refractive power change was strongly correlated to the Ortho-K lens base curve, it characterized only 50% of the target power change. However, the annular steepened zone refractive power change appears to be a clearer predictor of target power change, as there appears to be a one-to-one inverse relationship with the target refractive power correction. Differences between these results and the literature may be a result of the topography software smoothing effect.

8.
Diagnostics (Basel) ; 12(12)2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36553038

RESUMO

There are different fundamental diagnostic strategies for patients with ectatic corneal diseases (ECDs): screening, confirmation of the diagnosis, classification of the type of ECD, severity staging, prognostic assessment, and clinical follow-up. The conscious application of such strategies enables individualized treatments. The need for improved diagnostics of ECD is related to the advent of therapeutic refractive procedures that are considered prior to keratoplasty. Among such less invasive procedures, we include corneal crosslinking, customized ablations, and intracorneal ring segment implantation. Besides the paradigm shift in managing patients with ECD, enhancing the sensitivity to detect very mild forms of disease, and characterizing the inherent susceptibility for ectasia progression, became relevant for identifying patients at higher risk for progressive iatrogenic ectasia after laser vision correction (LVC). Moreover, the hypothesis that mild keratoconus is a risk factor for delivering a baby with Down's syndrome potentially augments the relevance of the diagnostics of ECD. Multimodal refractive imaging involves different technologies, including Placido-disk corneal topography, Scheimpflug 3-D tomography, segmental or layered tomography with layered epithelial thickness using OCT (optical coherence tomography), and digital very high-frequency ultrasound (VHF-US), and ocular wavefront. Corneal biomechanical assessments and genetic and molecular biology tests have translated to clinical measurements. Artificial intelligence allows for the integration of a plethora of clinical data and has proven its relevance in facilitating clinical decisions, allowing personalized or individualized treatments.

9.
J Refract Surg ; 38(11): 741-746, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36367262

RESUMO

PURPOSE: To report the first clinical experience with topical losartan for treating a case of severe corneal haze after complicated laser in situ keratomileusis (LASIK). METHODS: A 36-year-old woman presented with corneal haze in the left eye after femtosecond laser-assisted LASIK. The left eye had flap dislocation and significant striae, which had been re-lifted. Uncorrected distance visual acuity (UDVA) was 20/200 and corrected distance visual acuity was 20/30 in the left eye at the first presentation, 52 days after the first procedure. A dense layer of subepithelial opacity (haze) was noted in the left cornea. The patient elected to start the off-label treatment with topical losartan 0.8 mg/mL six times per day. RESULTS: Four and one-half months after initiating topical losartan, UDVA improved to 20/30 and CDVA improved to 20/25 in the left eye. A significant reduction of corneal haze was observed at the slit lamp and using Scheimpflug corneal tomography (Pentacam AXL; Oculus Optikgeräte GmbH) and anterior segment optical coherence tomography (Revo NX 130; Optopol). CONCLUSIONS: Losartan is an inhibitor of transforming growth factor-ß signaling. Topical treatment is promising to treat corneal haze formation after corneal injuries, chemical burns, and surgeries. Further clinical studies are needed to optimize losartan dosages and treatment durations. [J Refract Surg. 2022;38(11):741-746.].


Assuntos
Doenças da Córnea , Opacidade da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Feminino , Humanos , Adulto , Losartan/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Doenças da Córnea/cirurgia , Acuidade Visual , Opacidade da Córnea/etiologia , Transtornos da Visão/cirurgia , Fibrose , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
10.
Saudi J Ophthalmol ; 36(1): 17-24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35971484

RESUMO

Knowledge of biomechanical principles has been applied in several clinical conditions, including correcting intraocular pressure measurements, planning and following corneal treatments, and even allowing an enhanced ectasia risk evaluation in refractive procedures. The investigation of corneal biomechanics in keratoconus (KC) and other ectatic diseases takes place in several steps, including screening ectasia susceptibility, the diagnostic confirmation and staging of the disease, and also clinical characterization. More recently, investigators have found that the integration of biomechanical and tomographic data through artificial intelligence algorithms helps to elucidate the etiology of KC and ectatic corneal diseases, which may open the door for individualized or personalized medical treatments in the near future. The aim of this article is to provide an update on corneal biomechanics in the screening, diagnosis, staging, prognosis, and treatment of KC.

11.
Clin Ophthalmol ; 16: 2421-2428, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35957658

RESUMO

Purpose: The ability to predict corneal edema and understand its relationship with imaging parameters enables optimization of decision-making in terms of cataract surgery. Therefore, we aimed to elucidate the immediate tomographic alterations after phacoemulsification. Patients and Methods: In this prospective study, we evaluated clinical and corneal tomographic data of 30 patients with cataracts, obtained using a rotating Scheimpflug tomographic system before and after cataract surgery with a phacoemulsification system. Corneal thickness and volume were measured, and Pentacam Nucleus Staging, keratometry, and specular microscopy were performed preoperatively and immediately postoperatively. The Wilcoxon signed-rank test was used to compare pre-and postoperative values. We calculated the correlations between the changes in these values and multiple parameters related to phacodynamics, including "ultrasound (US) elapsed" (phaco time), "US average" (average power used), and "US absolute" (energy effectively dissipated, a product of the other two parameters). Results: There were increases in corneal volume (p<0.0001) and pachymetry (p<0.0001), and a decrease in endothelial cell count (p<0.0001) after surgery. The mean differences in pre- and postoperative specular microscopy, corneal volume, and pachymetry were -335.13±236.21 cells/mm3, 1.33±0.56 mm3, and 61.33±23.73 microns, respectively. The difference in pre-and postoperative corneal volume in patients with US elapsed ≥40 s was 0.75 mm3 greater than that in patients with US elapsed <40 s (95% confidence interval [CI]: 0.24-1.25; p=0.005); that of pachymetry in patients with US elapsed ≥40 s was 31.76 microns greater than that in patients with US elapsed <40 s (95% CI: 9.55-53.97; p=0.007). Spearman correlation revealed that, for every 1% increase in cataract density, the US average value increased by 0.31% (coef.: 0.3110; 95% CI: 0.0741-0.5490; p=0.012). Conclusion: Knowledge of Pentacam Nucleus Staging and the effect of US elapsed on differences in corneal volume and pachymetry before and after cataract surgery should be of particular value for surgeons who routinely encounter patients with hard cataracts.

12.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1376779

RESUMO

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Assuntos
Humanos , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos , Fenômenos Biomecânicos , Córnea/anatomia & histologia , Córnea/fisiologia , Pressão Intraocular/fisiologia , Glaucoma/fisiopatologia , Hipertensão Ocular/fisiopatologia , Técnicas de Diagnóstico Oftalmológico/instrumentação , Elasticidade/fisiologia , Modelos Teóricos
13.
Exp Eye Res ; 202: 108347, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33275919

RESUMO

Ectatic corneal disease (ECD) comprises a group of disorders characterized by progressive thinning and subsequent bulging of the corneal structure. Different phenotypes have been recognized, including keratoglobus, pellucid marginal degeneration (PMD), and keratoconus (KC). Keratoconus has been widely investigated throughout the years, but the advent of laser refractive surgery boosted an immediate need for more knowledge and research about ectatic diseases. This article discusses nomenclature of ectatic disease, etiology and pathogenesis, along with treatment options, with special focus ok KC and forme fruste keratoconus.


Assuntos
Córnea/patologia , Doenças da Córnea/patologia , Córnea/fisiopatologia , Doenças da Córnea/fisiopatologia , Topografia da Córnea , Elasticidade , Humanos
14.
J Biophotonics ; 13(10): e202000156, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32649048

RESUMO

The purpose of this study was to assess unique corneal tomographic parameters of allergic eye disease (AED) using optical coherence tomography (OCT) and artificial intelligence (AI). A total of 57 eyes diagnosed with AED were included. The curvature and aberrations of the air-epithelium (A-E) and epithelium-Bowman's layer (E-B) interfaces were calculated. Random forest AI models were built combing this data with the parameters of healthy, forme fruste keratoconus (FFKC) and KC eyes. The AI models were cross-validated with 3-fold random sampling. Each model was limited to 10 trees. The AI model incorporating both A-E and E-B parameters provided the best classification of AED eyes (area under the curve = 0.958, sensitivity = 80.7%, specificity = 98.5%, precision = 88.2%). Further, the E-B interface parameters provided the highest information gain in the AI model. A few AED eyes (n = 9) had tomography parameters similar to FFKC and KC eyes and may be at risk of progression to KC.


Assuntos
Topografia da Córnea , Ceratocone , Tomografia de Coerência Óptica , Inteligência Artificial , Córnea/diagnóstico por imagem , Humanos , Ceratocone/diagnóstico por imagem , Curva ROC
15.
J Refract Surg ; 36(6): 358-365, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32521022

RESUMO

PURPOSE: To compare clinical outcomes between topography-guided customized ablation treatment (TCAT) and wavefront-optimized (WFO) photorefractive keratectomy (PRK) in fellow eyes of myopic patients. METHODS: Forty-six eyes of 23 patients who underwent PRK were included. WFO ablation was performed in one eye (WFO group) and TCAT in the fellow eye (TCAT group). The customized treatment plan was based on the Topolyzer Vario topography system (Alcon Laboratories, Inc) data. The patients were observed for 12 months after the procedure. RESULTS: One year after the surgery, there was no significant difference in the manifest refraction spherical equivalent, sphere, or cylinder variables between the two groups (P > .05). In both groups, 96% of eyes achieved an uncorrected distance visual acuity of 20/20 or better at 12 months postoperatively. Accuracy, safety, and efficacy of the refractive and visual outcomes were similar in the two groups. The postoperative higher order aberrations magnitude was lower in the TCAT group, but this was not statistically significant (P > .05). During the 12-month follow-up, no patient described any symptoms related to glare, halos, or starbursts in either eye. Other postoperative complications, such as infection or cor-neal infiltrates, did not occur in either group. CONCLUSIONS: TCAT and WFO ablations provided similar outcomes after PRK for myopia and myopic astigmatism correction. There were no statistically significant differences in postoperative corneal wavefront analysis. [J Refract Surg. 2020;36(6):358-365.].


Assuntos
Astigmatismo/cirurgia , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/cirurgia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Adulto , Astigmatismo/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Miopia/fisiopatologia , Complicações Pós-Operatórias , Estudos Prospectivos , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
16.
Ophthalmol Ther ; 9(2): 355-363, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32323165

RESUMO

Corneal ectasia is a complication of refractive surgery, and keratoconus is a contraindication to this type of procedure. Surface ablation may be an option for selected cases of mild keratoconus, with patient education being fundamental to this treatment as well as a complete evaluation of the cornea and optical properties of the patient. Here we report the clinical outcome of a patient 15 years after advanced surface ablation in a case of mild (fruste) keratoconus.

17.
Artigo em Inglês | MEDLINE | ID: mdl-32209975

RESUMO

PURPOSE: To review the role of corneal biomechanics for the clinical evaluation of patients with ectatic corneal diseases. METHODS: A total of 1295 eyes were included for analysis in this study. The normal healthy group (group N) included one eye randomly selected from 736 patients with healthy corneas, the keratoconus group (group KC) included one eye randomly selected from 321 patients with keratoconus. The 113 nonoperated ectatic eyes from 125 patients with very asymmetric ectasia (group VAE-E), whose fellow eyes presented relatively normal topography (group VAE-NT), were also included. The parameters from corneal tomography and biomechanics were obtained using the Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). The accuracies of the tested variables for distinguishing all cases (KC, VAE-E, and VAE-NT), for detecting clinical ectasia (KC + VAE-E) and for identifying abnormalities among the VAE-NT, were investigated. A comparison was performed considering the areas under the receiver operating characteristic curve (AUC; DeLong's method). RESULTS: Considering all cases (KC, VAE-E, and VAE-NT), the AUC of the tomographic-biomechanical parameter (TBI) was 0.992, which was statistically higher than all individual parameters (DeLong's; p < 0.05): PRFI- Pentacam Random Forest Index (0.982), BAD-D- Belin -Ambrosio D value (0.959), CBI -corneal biomechanical index (0.91), and IS Abs- Inferior-superior value (0.91). The AUC of the TBI for detecting clinical ectasia (KC + VAE-E) was 0.999, and this was again statistically higher than all parameters (DeLong's; p < 0.05): PRFI (0.996), BAD-D (0.995), CBI (0.949), and IS Abs (0.977). Considering the VAE-NT group, the AUC of the TBI was 0.966, which was also statistically higher than all parameters (DeLong's; p < 0.05): PRFI (0.934), BAD- D (0.834), CBI (0.774), and IS Abs (0.677). CONCLUSIONS: Corneal biomechanical data enhances the evaluation of patients with corneal ectasia and meaningfully adds to the multimodal diagnostic armamentarium. The integration of biomechanical data and corneal tomography with artificial intelligence data augments the sensitivity and specificity for screening and enhancing early diagnosis. Besides, corneal biomechanics may be relevant for determining the prognosis and staging the disease.


Assuntos
Inteligência Artificial , Córnea , Paquimetria Corneana , Topografia da Córnea , Córnea/diagnóstico por imagem , Dilatação Patológica , Alemanha , Humanos , Curva ROC , Estudos Retrospectivos
18.
Eye Vis (Lond) ; 7: 9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32042837

RESUMO

Corneal biomechanics has been a hot topic for research in contemporary ophthalmology due to its prospective applications in diagnosis, management, and treatment of several clinical conditions, including glaucoma, elective keratorefractive surgery, and different corneal diseases. The clinical biomechanical investigation has become of great importance in the setting of refractive surgery to identify patients at higher risk of developing iatrogenic ectasia after laser vision correction. This review discusses the latest developments in the detection of corneal ectatic diseases. These developments should be considered in conjunction with multimodal corneal and refractive imaging, including Placido-disk based corneal topography, Scheimpflug corneal tomography, anterior segment tomography, spectral-domain optical coherence tomography (SD-OCT), very-high-frequency ultrasound (VHF-US), ocular biometry, and ocular wavefront measurements. The ocular response analyzer (ORA) and the Corvis ST are non-contact tonometry systems that provide a clinical corneal biomechanical assessment. More recently, Brillouin optical microscopy has been demonstrated to provide in vivo biomechanical measurements. The integration of tomographic and biomechanical data into artificial intelligence techniques has demonstrated the ability to increase the accuracy to detect ectatic disease and characterize the inherent susceptibility for biomechanical failure and ectasia progression, which is a severe complication after laser vision correction.

19.
PLoS One ; 14(7): e0219789, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31348792

RESUMO

PURPOSE: To present a three-dimensional non-parametric method for detecting scleral asymmetry using corneoscleral topography data that are free of edge-effect artefacts. METHODS: The study included 88 participants aged 23 to 65 years (37.7±9.7), 47 women and 41 men. The eye topography data were exported from the Eye Surface Profiler software in MATLAB binary data container format then processed by custom built MATLAB codes entirely independent from the profiler software. Scleral asymmetry was determined initially from the unprocessed topography before being determined again after removing the edge-effect noise. Topography data were levelled around the limbus, then edge-effect was eliminated using a robust statistical moving median technique. In addition to comparing raw elevation data, scleral elevation was also compared through fitting a sphere to every single scleral surface and determining the relative elevation from the best-fit sphere reference surface. RESULTS: When considering the averaged raw topography elevation data in the scleral section of the eye at radius 8 mm, the average raw elevations of the right eyes' sclera were -1.5±1.77, -1.87±2.12, -1.36±1.82 and -1.57±1.87 mm. In the left eyes at the same radius the average raw elevations were -1.62±1.78, -1.82±2.07, -1.28±1.76 and -1.68±1.93 mm. While, when considering the average raw elevation of the sclera after removing the edge effect, the average raw elevations of the right eyes were -3.71±0.25, -4.06±0.23, -3.95±0.19 and -3.95±0.23 mm. In the left eyes at the same radius the average raw elevations were -3.71±0.19, -3.97±0.22, -3.96±0.19 and -3.96±0.18 mm in the nasal, temporal, superior and inferior sides respectively. Maximum raw elevation asymmetry in the averaged scleral raw elevation was 1.6647±0.9015 mm in right eyes and 1.0358±0.6842 mm in left eyes, both detected at -38° to the nasal side. Best-fit sphere-based relative elevation showed that sclera is more elevated in three main meridians at angles -40°, 76°, and 170° in right eyes and -40°, 76°, and 170° in left eyes, all measured from the nasal meridian. Maximum recorded relative elevation asymmetries were 0.0844±0.0355 mm and 0.068±0.0607 mm at angular positions 76° and 63.5° for right and left eyes in turn. CONCLUSIONS: It is not possible to use corneoscleral topography data to predict the scleral shape without considering a method of removing the edge-effect from the topography data. The nasal side of the sclera is higher than the temporal side, therefore, rotationally symmetric scleral contact lenses are more likely to be translated towards the temporal side. The scleral shape is best described by levelled raw elevation rather than relative elevation.


Assuntos
Artefatos , Topografia da Córnea , Esclera/anatomia & histologia , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...